UBC355XLTScanner
10Band Frequency Coverage (MHz)Mode Steps (kHz) Service25 – 28 25.0000 to 27.9950 AM 5 AM Band28- 70 28.0000 - 69.9950 FM 5 10 - 6 Meter Am
11Band Frequency Coverage (MHz)Mode Steps (kHz) Service400-520 400.0000 - 520.0000 FM 6.25 Land Mobile Radio*806-956 806.0000 - 956.0000 FM
12Frequency Band Hum and Noise (Nominal)25.000 - 27.995 48 dB28.000 - 88.000 43 dB108.0000 - 136.9875 48 dB148.0000 - 174.0000 43 dB400.0000 - 520.00
13• Fixable Mobile Antenna• AC Adapter • Vehicle Power Adapter • DC Power Cord for hard-wiring power from your car to your scanner. • Bracket• S
14Visit our online store via our website; www.uniden.com.au for Australia or www.uniden.co.nz for New Zealand.INSTALLING THE UBC355XLT SCANNERFOR HOME
15multi-band coverage. (You can purchase this type of antenna at a local electronics store.) • If the optional antenna has no cable, use 50-70 ohm co
16Permanent Mobile InstallationPermanently installing the UBC355XLT scanner into a vehicle involves two main steps - physically installing the scanner
174. Mount the scanner to the bracket only after the wiring has been connected to the rear panel. Permanently Connecting the Mobile Power SupplyCAUTI
18SCANNER OPERATION OVERVIEWUBC355XLT FRONT PANELKEY PURPOSEHold Press this key to stop scanning or searching and to remain on the current frequency.
19KEY PURPOSEUp and Down Press these directional keys to:• Manually search up or down for frequencies while in Hold mode.• Change direction of a sea
2IMPORTANT INFORMATIONPRECAUTIONSBefore you use this scanner, please observe the following: Warning Uniden does not represent this unit to be waterpro
20KEY PURPOSEPolice/Rail Press this key to scan the Police and Railroad bands. Pressing this key cycles through the frequencies in the following order
21KEY PURPOSEFire/Ambl Press this key to scan the Fire and Ambulance bands. Pressing this key cycles through the frequencies in the following order:•
22KEY PURPOSEClose Call Press this key to begin monitoring for strong, nearby signals. Pressing this key cycles through the frequencies in the followi
23KEY PURPOSEAir/Marine Press this key to scan the Air and Marine bands. Pressing this key cycles through the frequencies in the following order:• Ai
24KEY PURPOSEL/O Press this key to temporarily or permanently lock out frequencies or channels from being searched or scanned. (L/O is explained in mo
25ITEM PURPOSEVolume/O Volume Control/Power SwitchTurn this control clockwise to turn on the UBC355XLT unit. Continue turning this control clockwise
26UBC355XLT REAR PANELITEM PURPOSEANT BNC Antenna Connector. Insert the antenna plug here.EXT SP External Speakers. Insert optional external speaker
27USING YOUR UBC355XLT SCANNERSET UPAdjusting Squelch To Adjust Squelch - 1. Turn SQ completely counterclockwise. You should hear open squelc
28OPERATING MODESThe UBC355XLT operates in two modes - Scan and Search: SCAN Scanning allows you to scan through channels in various service banks.Pre
29SEARCHSearch lets you search through pre-grouped bands of frequencies. Press Band key to select 1 of 8 separate frequency bands to search. Press the
3TABLE OF CONTENTSIMPORTANT INFORMATION ...2PRECAUTIONS ...2Warning ...
30NOTE: The Police and Railroad banks share 100 PRIVATE channels. These user-programmed channels are scanned after pre-programmed channels.Pressing Fi
31Pressing UCB/CB more than once will cycle through the banks in this order:1. UHF CB/ AM CB2. UHF CB3. AM CB4. NoneScanning Service Bank TipsIf Y
32If You Want to do This - Here’s How - Set up multiple service banks to scanPress a desired service bank’s key until it displays. Continue pressing
33If You Want to do This - Here’s How - Resume scanning (Cont.)• Any bank key - If you press a dierent bank key, you will start scanning in that ne
34Searching Band TipsIf You Want to Do This - Here’s How - Begin searching Press the Band key. The screen displays the last known searched band and t
35SCREENSThis section shows typical screen displays:SCANNING BANKSThis screen shows UBC355XLT is actively scanning a displayed bank. “SCAN“scrolls fro
36SEARCHING BANDSWhen Band is pressed, this screen displays the band range to be searched. Press Band again (or Up/Down within 3 seconds) to see other
37• Private Bank• Program Frequencies into Programmable Banks.• Program LockLOCK OUT CHANNELS / FREQUENCIES Sometimes the scanner may stop on a par
38Permanent Lock OutPressing L/O twice permanently locks out the current frequency or channel. The scanner displays “L/O” for that frequency or channe
39can also lock out all channels.) If you lock out all the channels or frequencies in one of these banks, pressing that bank key will make the scanner
4Adjusting Squelch ...27OPERATING MODES ...28SCAN ...
40If You Want to Do This - Here’s How - Temporary Lock Out (Cont.)• Press the bank you were scanning to resume scanning in that bank.• Press a di
41If You Want to Do This - Here’s How - Restoring a Single Locked-Out Channel or Frequency(Example: Channel 12 of the Private bank is locked out.)1.
42If You Want to Do This - Here’s How - Restoring a Single Locked-Out Channel (Cont.)4. “L/O” disappears to indicate that Channel 12 is now unlocked
43If You Want to Do This - Here’s How - Restoring All Permanently Locked Out Channels/Frequencies (Cont.)3. Press and hold L/O for more than 2.5 s
443. Close Call OPressing and holding the key activates Close Call Only mode.Close Call PriorityRepeatedly press until the Close Call Priority
45Setting Up Close Call Modes1. Press and hold to enter the Close Call Only mode. The screen displays a line of dashes. 2. Press again to d
46Band Name Frequency (MHz)b1 Lo VHF Low Band 25.0000 - 88.0000b2 Air AIR Band 108.0000 - 136.9875b3 Hi VHF High Band 137.0000 - 174.0000b4 UHF UHF B
472. Scroll up or down to select bands for Close Call to monitor. Press Prog. The screen displays that selection and “On.” You cannot turn o all b
48Close Call TipsIf You Want To - Here’s How - Scan for Close Call Transmissions while Scanning other Banks/BandsPress the key. The Close Call icon
49If You Want To - Here’s How - Save a Frequency Found Through Close Call (Cont.)2. Press any key to conrm the frequency.3. Follow the steps for “
5Setting C ‐ Options ...45Setting C ‐ Options ...47Setting C ‐ C.PS Options ... 4
50Programming Frequencies and ChannelsUp to 100 frequencies (1 frequency per channel) can be programmed into each of the following banks (300 frequenc
51Programming a ChannelThe following steps detail how to program a frequency into a channel for a specic bank when the frequency was found while scan
52Press the key for the bank you want to program. In this example, Police/Rail was pressed.The screen cycles between two displays. The rst screen sho
53 Press Prog. The scanner programs the frequency into the indicated channel and then goes into SCAN HOLD mode. Press Hold to release the Hold and
54 Frequency changes to 000.0000 and CH continues ashing. Press the bank containing the channel you wish to clear. The screen displays the rst
55 The screen cycles between two displays. The rst screen shows that channel 6 on the Police bank (75.86250) is selected and the second screen s
56PROGRAM LOCK FEATURE The UBC355XLT has a Program Lock feature to prevent accidentally programming entries or unauthorized programming. Press and hol
57TROUBLESHOOTING GUIDEPROBLEM SOLUTION Scanner won’t workTry one of these options:• Check the connections at both ends of the AC adapter.• Turn on
58PROBLEM SOLUTION Improper ReceptionTry one of these options:• Check the antenna and its connection.• Move the scanner. • You may be in a fringe a
59PROBLEM SOLUTION Scan won’t start Try one of these options:• Press the bank key again. • Adjust the Squelch Control.• Program frequencies into
6ABOUT YOUR NEW UBC355XLT SCANNERThe UBC355XLT comes with 8 Service banks for monitoring police, railroad, re, ambulance, air, marine, UHF CB and CB
60GENERAL PRODUCT CARETurn the scanner o before disconnecting the power. Always press each keypad button rmly until you hear the entry tone for that
61Clean the outside of the scanner with a soft cloth. To prevent scratches, do not use abrasive cleaners or solvents. Be careful not to rub the LCD wi
62 TECHNICAL SPECIFICATIONSSize: 132mm (W) x 142mm (D) x 42mm (H)Weight: 640gOperating Temperature: – 20ºC (– 4ºF) to + 60ºC (+ 140ºF) Power Requireme
63 shared with Fire• Air (AIR): 1,520 Preprogrammed.• Marine (MRN): 89 Preprogrammed.• UHF CB (UCB): 40 programmed• AM CB (CB): 40 (40 Australia m
65WARRANTYUBC355XLT SCANNERIMPORTANT: Satisfactory evidence of the original purchase is required for warranty servicePlease refer to our Uniden websit
66(C) Improperly installed contrary to instructions contained in the relevant Owner’s Manual(D) Repaired by someone other than an authorized Unide
67UNIDEN NEW ZEALAND LTDService Division150 Harris Road, East TamakiAuckland 2013Phone: (09) 273 8377Email: [email protected] for obtainin
Thank you for buying a uniden producT.© 2010 Uniden Australia Pty Limited. Uniden New Zealand Ltd. Printed in PRC.UBZZ01362AA(0)
7The country mode can be switched between Australia and New Zealand as follows:• Turn on the power while pressing down the Hold key. The display will
8 » POLICE: 340 (207 Australia mode + 133 New Zealand mode) Factory-programmed Police frequencies with 100 open channels (shared with Railroad), allo
9Note: The Fire and Ambulance banks share a single key - Fire/Ambl. Pressing this key will toggle between the banks. Additional information is provide
Kommentare zu diesen Handbüchern