Uniden UPBX 416 Spezifikationen Seite 1

Stöbern Sie online oder laden Sie Spezifikationen nach Vernetzung Uniden UPBX 416 herunter. Uniden UPBX 416 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Public Dial Restriction
This feature allows assigned telephone number restrictions to be entered
or removed. For example, if you enter 1(800)555-5555 which has 11
digits, this exact phone number is blocked for outgoing calls. You can
have 8 codes and up to 25 digits of restricted numbers.
Operation:
To INPUT public dial restriction code:
1. Set the MODE Switch on the right side of the unit to Set-Up Mode
2. Lift the handset connected to Ext. 200 - the dial tone is heard in the receiver.
3. Press to enter the feature.
4. Press to enter the code number. (max. 8 codes)
5. Press telephone number to be restricted. (max. 25 digits)
6. Press to set.
7. Replace the handset.
8. Set the MODE Switch on the right side of the unit to Business-Hour Mode
To FREE public dial restriction code:
1. Set the MODE Switch on the right side of the unit to Set-Up Mode
2. Lift the handset connected to Ext. 200 - the dial tone is heard in the receiver.
3. Press to enter the feature.
4. Press to enter the code number. (max. 8 codes)
5. Press to free.
6. Replace the handset.
7. Set the MODE Switch on the right side of the unit to Business-Hour Mode
4
1
8
#
N
4
S
1
8
#
N
Telephone No.
4
S
1
8
N
4
1
8
N
S
S
32
(
(
(
(
(
(
(
(
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - Public Dial Restriction

Public Dial RestrictionThis feature allows assigned telephone number restrictions to be enteredor removed. For example, if you enter 1(800)555-5555 wh

Seite 2

Uniden UPBX416Communication Centre41

Seite 3 - Telephone No

INSTALLATION & INTRODUCTIONOnce the Uniden UPBX416 and the Personal Computer (PC) are connected through the serialcable, turn both of these on.1.

Seite 4 - VERSATILE EXCHANGER SETTINGS

Job Menu:Setup - (Also in the Toolbar)Configures your UPBX using agraphical user interfaceUpgrade - (Also in the T

Seite 5 - Operation :

ToolbarThe UPBX Communication Centre Toolbar gives you quick and easy access to some of its mostfrequently used menu items. To select an item on the t

Seite 6

The UPBX toolbar gives you quick and easy access to some of its most frequently usedmenu items. To select an item on the toolbar simply place your mou

Seite 7

Multi-Attendant Mode:This is used when incoming calls from the respective C.O. line are required to be receiveddirectly by corresponding stations alre

Seite 8

Off-Hour Mode:An alternate recorded message can be played during off- hours, weekends, and holidays.OGM 6 is played instead of OGM1. In the Off Hour M

Seite 9 - Selection’

This code restricts the first 4 digits of telephone number. COS restriction code can beentered when there are codes which should be uniformly restrict

Seite 10 - Communication Centre

Initialising the SystemThis initialises the system and erases all previous inputs. There are two ways of initialisingthe system - by including or excl

Seite 11 - Menu Items

This WARNING message willappear. Press continue buttonto proceed.Downloading the Firmware CodeThe UPBX’s firmware programme or operating code can be d

Seite 12 - Help Menu:

Station Public Dial RestrictionThe 8 restriction codes you have entered (see page 32), now need to be registered to eachextension to activate restrict

Seite 13 - Status Bar

Checking the Firmware VersionYou can get the information of EPROM programme version in the unit.Managing the SMDR (Station Message Detail Recording)St

Seite 14 - HOW TO USE

Date/TimeSet the current date and timeto get the correct voice mailservices. Date and time aredisplayed on UPBX416Communication Centre fromsettled dat

Seite 15 - Exchanger Setup Tab

TROUBLESHOOTINGProblems Check Point (or Remedy)The unit does not work. Check power source- Is the power adaptor correctly plugged in ?- Is the telepho

Seite 16

Power Failure or OffYou can use the telephone during a power failure or off. You can use Line1 and Line 2with station 200 and 201.System Initialisatio

Seite 17

When setting the features with you must put the mode switch on the set-upmode and do it at ext. 200.You will hear a long dial tone to enable the

Seite 18 - Initialising the System

Managing Own Voice MailboxPassword RegistrationRecording Station OGMChecking Station OGMTo checkTo change to system OGMTo change to your own OGMManagi

Seite 19 - Downloading the Firmware Code

Managing ICMs From a Remote Telephone (Remote Control)To check:1. Call your telephone number.2. Press when you hear the station or system OGM

Seite 20 - Checking the Firmware Version

Basic Telephony OperationsIntercom CallsPress (this means choose any extension between 200 and215 that you wish to call).Outsid

Seite 21 - Date/Time

Attendant SelectionAuto Attendant ModeAttendant Mode (Default Setting)Multi-Attendant ModeAssigning Attendant TelephoneASSIGNCANCELWhen Leaving a Desk

Seite 22 - TROUBLESHOOTING

Call ForwardingCall Forwarding to Extension NumberREGISTER and SETCANCELCall Forwarding OutsideREGISTERSETCANCELMemory DialExtension Memory Dial Input

Seite 23 - System Initialisation

Emergency Code FreeThis feature will unlock the previously restricted numbers. If you restricted 911 (inthis case 3 digits) then this will unlock the

Seite 24 - UPBX COMMAND (DTMF) SUMMARY

Off Hour / Business Hour ServicesCall IDENABLECANCELHot Line (Boss and Secretary Mode)REGISTER and SETCANCELOff Hour / Business Hour ServicesSetting t

Seite 25 - Managing Own Voice Mailbox

62Flash Time adjustment for C.O. LinesFlash Time Adjustments for ExtensionsMusic On HoldINTERNALEXTERNALSELECTING Printout for SMDRTo PCTo SERIAL PORT

Seite 26 - To check:

63NOTIFICATION on 3 Way CallingESTABLISHCANCELC.O. Ring Assignment (Multi Attendant)Dial RestrictionClass of Service (COS) Code RestrictionENTERREMOVE

Seite 27

64TECHNICAL SPECIFICATIONSystem ConfigurationC.O. line: 4 linesExtension: 16 ExtensionsPower: 24V DC, 1.2A AC AdaptorFeaturesDial:- Extension memo

Seite 28 - Assigning Attendant Telephone

Class of Service(COS) Code A group of parameters which can be adjusteddifferently for each restriction code.DIDS Direct Inward Dialling

Seite 31 - 2 0 0 2 1 5

Caller IDThe telephone company feature ‘Caller ID’ is passed through to the unit between thefirst and second rings. If the Auto Attendant (OGM) has be

Seite 32

Hot Line (Boss and Secretary Mode)You can have a maximum of 4 Hot Lines. The Boss Line is automatically connectedto the Secreatary station each time t

Seite 33 - TECHNICAL SPECIFICATION

Flash Time Adjustment for C.O. LinesThe Flash time means the actual time it takes to depress and release the plunger or theactual handset-cradle to cr

Seite 34 - GLOSSARY

Selecting Printout for SMDR (Extension Message Detail Recording)Extension message detail recording (SMDR) is a type of telephone call accounting thati

Seite 35 - WARRANTY

Adjusting the Maximum Recording Length of ICM and OGMAdjust the maximum length (“1~10 minutes”) of outgoing messages and incomingmessage to be left in

Seite 36

Registering Group for a call pick-upYou can have a maximum of 4 groups. Group 1 is able to pick-up calls from all extensions.You can pick up a call in

Kommentare zu diesen Handbüchern

Keine Kommentare