Vivace Boat Information Book Web Version (BIB) (Rev February 13, 2014)
Revision 6 Page | 63
Propane Stove Information
This system is designed for use with Liquefied propane gas (LPG)
Only. Do not connect compressed natural gas (CNG) to this system.
Precautions:
1. Test the system for leakage in accordance with the procedures
below each time an LPG cylinder is connected.
2. Disconnect LPG cylinder when boat is unattended.
3. Close solenoid valve when stove is not in use.
4. Close all stove valves and solenoid valve immediately in any emergency.
5. Remove empty cylinders from boat.
6. Close all stove valves when connecting LPG cylinder.
7. Apply ignition source to burner before opening burner valve.
8. LPG locker shall not be used for storage of any equipment other than LPG
cylinders, valves, regulating equipment and LPG safety devices.
LPG Stove Operating Procedure
Before Using the LPF System Complete the Following Leak Test:
1. Close solenoid valve (LPG switch on electrical panel - OFF).
2. Close all stove valves.
3. Connect LPG bottle to LPG line.
4. Open solenoid valve (switch on electrical panel -- ON).
5. Observe pressure gauge reading.
6. Close solenoid valve (LPG switch on electrical panel -- OFF).
7. Pressure indication should remain constant for not less than 3 minutes.
8. Check for gas odor.
9. lf leakage is detected during this test, disconnect and reconnect LPG
cylinder, Then repeat test.
10. lf leakage is detected during second test disconnect LPG cylinder and
do not use LPG system.
Starting Stove
1. Open solenoid valve (LPG switch on electrical panel - ON).
WARNING
(ABYC Standard A-1, 1.5.4)
Liquefied propane gas (LPG) is flammable and explosive.
Follow these instructions to avoid death or injury from fire or
explosion.